MODELS: G 1006T/SS316 OPERATING INSTRUCTIONS, INSTALLATION & MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST
PUMP MODEL G1006TSS VER 1.01/1/2011D.NO. PART NO. DESCRIPTION QTY1a 405-076-24 DISCHARGE OUTLET (6" NPT) 11b 405-051-24 DISCHARGE OUTLET (6&qu
PUMP MODEL G1006TSS VER 1.0D.NO. PART NO. DESCRIPTION QTY49 600-058-24 TRIMMING SPACER AS REQD50 080-017-21 CIRCLIP 251 535-040-00 MECHANICAL SEAL
LIMITED WARRANTY We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects in ma
LLIIFFEE IISS PPRREECCIIOOUUSS -- TTHHIINNKK SSAAFFEETTYY 1. Most accidents can be avoided by using COMMON SENSE. 2. Please read the
GENERAL INFORMATION. THE “mody” PORTABLE SUBMERSIBLE PUMPS CONSIST OF A SQUIRREL CAGE INDUCTION MOTOR DRIVING A CENTRIFUGAL PUMP. THE PUMP IMPELL
INSTALLATION. • CHECK THAT THE SITE VOLTAGE CORRESPONDS WITH THAT OF THE PUMP. • CHECK THAT FUSES ARE INTACT. • USE SHORTEST POSSIBLE HOSE IN
TROUBLE GUIDE CAUSE REMEDY 1.FUSES BLOWN. 1.REPLACE FUS
GENERAL OVERHAUL AND OIL CHECK. REFER DRAWINGS DWG/885/00 (SHEET 1 & 2) AT END OF MANUAL. • ALWAYS REPLACE O-RINGS WITH NEW ONES WHENEVER
• LOOSEN SCREWS AND REMOVE CABLE CLAMP. LOOSE NUTS AND WITH THE HELP OF TWO SCREWDRIVERS, PRY OUT CABLE GLAND. THE GLAND BASE WITH THE COMPLETE A
RECOMMENDED SPARES FOR TWO YEARS • 1 DIFFUSER RING • 1 DIFFUSER CENTER • 1 IMPELLER • 1 WEAR PLATE • 1 ‘O’ RING SET • 1 SET OF BEARINGS • 1