Mody-pumps G 506_536_556T_SS316 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes Mody-pumps G 506_536_556T_SS316. Mody Pumps G 506_536_556T_SS316 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
MODELS: G 506/536/556T/SS316
OPERATING INSTRUCTIONS, INSTALLATION & MAINTENANCE
MANUAL INCLUDING SPARE PARTS LIST
Mody Pumps Inc.
2166 Zeus Court
Bakersfield, CA 93308
Tel.: (661) 392-7600 FAX.: (661) 392-7601
http://www.modypump.com
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - Mody Pumps Inc

MODELS: G 506/536/556T/SS316 OPERATING INSTRUCTIONS, INSTALLATION & MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST

Page 2 - Mody Pumps Inc.:

R: RECOMMENDED SPARES FOR TWO YEARS OPERATION SR.NO DESCRIPTION PART NO. RECOMMENDED QTY. 1. MEC

Page 6

PUMP MODEL G506T-SS VER 1.0D.NO. PART NO. DESCRIPTION QTY1 065-014-79 CABLE 50'2 230-004-24 CABLE GLAND 13 085-022-24 CABLE CLAMP 14 525-021-24

Page 7 - DISMANTLING AND OVERHAULING

PUMP MODEL G506T-SS VER 1.0D.NO. PART NO. DESCRIPTION QTY50 370-005-24 HEX NUT 451 600-034-24 CAP FOR CIRCLIP 152 150-004-74 OIL DIAPHRAGM 153 525-02

Page 10

PUMP MODEL G536T-SS/E VER 1.0D.NO. PART NO. DESCRIPTION QTY1 065-016-79 CABLE 50'2 660-093-00 CABLE GLAND with GRIP

Page 11

PUMP MODEL G536T-SS/E VER 1.0D.NO. PART NO. DESCRIPTION QTY50 370-005-24 HEX NUT 451 600-034-24 CAP FOR CIRCLIP 152 150-0

Page 12

LLIIFFEE IISS PPRREECCIIOOUUSS -- TTHHIINNKK SSAAFFEETTYY 1. Most accidents can be avoided by using COMMON SENSE. 2. Please read the

Page 15

PUMP MODEL G556T-SS VER 1.0D.NO. PART NO. DESCRIPTION QTY1 065-016-79 CABLE 50'2 660-093-00 CABLE GLAND with GRIP 13 085-022-24 CABLE C

Page 16

PUMP MODEL G556T-SS VER 1.0D.NO. PART NO. DESCRIPTION QTY50 370-005-24 HEX NUT 451 600-034-24 CAP FOR CIRCLIP 152 150-004-74 OIL DIAPHRAGM 1

Page 17

LIMITED WARRANTY We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects in ma

Page 18

INTRODUCTION THE “mody” MOTOR DRIVEN PORTABLE SUBMERSIBLE PUMPS HAVE BEEN DEVELOPED DUE TO A LONG FELT NEED OF HAVING A TRULY MAINTENANCE FREE PUMP

Page 19

OVERALL DIMENSIONS AND WEIGHT: G 506TSS G536TSS G556TSS OVERALL HEIGHT (Approx.) 25” 28” 29” MAX. DIA

Page 20

MAINS VOLTAGE AT SITE HRC FUSE RECOMMENDED 220 VOLTS / 3 PHASE 20 AMPE

Page 21

THE SEAL CHAMBER THE HEART OF THE MODY PUMP. DUAL MECHANICAL, SILICON CARBIDE V/S SILICON CARBIDE SEAL FACES (LOWER SEAL) AND SILICON CARBIDE V/S SI

Page 22

ELECTRICAL INFORMATION: MOTORS ARE DESIGNED TO OPERATE ON SINGLE VOLTAGE AND FREQUENCY. MAX. DEVIATION IN VOLTAGE ALLOWED IS + - 6 % AND FREQUENCY

Page 23

9. CHECK BOTH UPPER AND LOWER BEARINGS (9 & 68) FOR ANY RADIAL OR AXIAL PLAY OR ANY ABNORMAL NOISE WHILE SPINNING THE SAME. CHECK FOR ANY LEAKAG

Page 24 - LIMITED WARRANTY

10. TURN OIL BAG INSIDE OUT AND FIT OIL BAG "VEE" SECTION INTO GROOVE IN SEAL HOUSING (28). USING SMALL OIL BAG CLAMPS AND SCREWS & NUT

Commentaires sur ces manuels