MODEL: M100T/316SS SERIES OPERATING INSTRUCTIONS, INSTALLATION & MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST Mody Pumps Inc. 2166 Z
PUMP MODELS M100T/100ST/106T/106ST/120T/126T Ref : Drawing no. DW/041/00D.NO. PART NO. DESCRIPTION QTY1 270-017-24 HANDLE 12 045-007-24 HEX. HD. BOLT
PUMP MODELS M100T/100ST/106T/106ST/120T/126T Ref : Drawing no. DW/041/00D.NO. PART NO. DESCRIPTION QTY43a 405-036-24 OUTLET 2" NPT SS 143b 405-00
LIMITED WARRANTY We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects in ma
LLIIFFEE IISS PPRREECCIIOOUUSS -- TTHHIINNKK SSAAFFEETTYY 1. Most accidents can be avoided by using COMMON SENSE. 2. Please read the
WARNING !!! Mody Single Phase Pumps Must be Run Using a Capacitor Pump Panel. Wiring Schematic is at the end of this manua
TECHNICAL DATA MOTOR 2-POLE SQUIRREL-CAGE AC MOTOR CLASS ‘H’ INSULATION (180C°) FOR 3-PHASE OR SINGLE PHASE ELECTRIC SUPPLY. MO
INSTALLATION AND MAINTENANCE. • CHECK THAT THE SITE VOLTAGE AND POWER SUPPLY CORRESPOND TO THAT OF THE PUMP. • CHECK THAT THE
OVERLOAD PROTECTION. IT IS ESSENTIAL THAT A STARTER BE USED WHEN OPERATING THE PUMP. CHOOSE THE CORRECT RATING OF STARTER AS PER
DISMANTLING (REFER DRG. DW/041/00-- SHEET 1 & 2). PLEASE NOTE THE DIFFERENT DRAWING NUMBERS FOR VARIOUS MODELS IN THE SERIES
RE-ASSEMBLY(REFER DRG. NO. DW/041/00-- SHEET 1 & 2). • THE REVERSE OF LAST TWO STEPS (OF THE DIS-ASSEMBLY PROCEDURE) CAN B
RECOMMENDED SPARES FOR TWO YEARS OPERATION SR. NO. DESCRIPTION PART NO. RECOMMEN