MODELS: G 702 TM, G 706 TM OPERATING INSTRUCTIONS, INSTALLATION & MAINTENANCE MANUAL INCLUDING SPARE PARTS LIST
13. SLIDE ON WEAR PLATE AGAINST LOWER BEARING BRACKET AND TIGHTEN THE SAME. FIT KEY ON THE SHAFT AND SLIDE ON IMPELLER. CLEARANCES BETWEEN IMPELLER
PUMP MODEL G702TM1.1.2012Sr.NO. PART No. DESCRIPTION QTY1a 405-057-21 DISCHARGE OUTLET (6" NPT)11b 405-109-21 DISCHARGE OUTLET (6" BSPT
PUMP MODEL G702TM 1.1.2012Sr.NO. PART No. DESCRIPTION QTY54 380-010-66 "O" RING 155 660-101-00 GLAND WITH GRIP ASSY. (Order with Gland)
PUMP MODEL G706TM1.1.2012Sr.NO. PART No. DESCRIPTION QTY1a 405-061-21 DISCHARGE OUTLET (4" NPT)11b 405-110-21 DISCHARGE OUTLET (4" BSPT
PUMP MODEL G706TM1.1.2012Sr.NO. PART No. DESCRIPTION QTY54 380-005-66 "O" RING 155 380-010-66 "O" RING 156 660-101-00 GLAND W
LLIIFFEE IISS PPRREECCIIOOUUSS -- TTHHIINNKK SSAAFFEETTYY 1. Most accidents can be avoided by using COMMON SENSE. 2. Please read the
LIMITED WARRANTY We warrant to our immediate customer and to the ultimate consumer that products of our manufacture will be free of defects in ma
INTRODUCTION THE “mody” ELECTRIC DRIVEN PORTABLE SUBMERSIBLE PUMPS HAVE BEEN DEVELOPED DUE TO A LONG FELT NEED OF HAVING A TRULY MAINTENANCE FREE
OVERALL DIMENSIONS AND WEIGHT. OVERALL HEIGHT 33.00”/825mm (APPROX.) MAX. DIAMETER 14.20”/360mm (APPROX.) MAX. WEIGHT (EX
MAINS VOLTAGE AT SITE HRC FUSE RECOMMENDED 220 VOLTS / 3 PHASE 63 AMPERES 380
TECHNICAL DESCRIPTION. THE MODY SUBMERSIBLE PUMP IS IN ITSELF A COMPLETE PUMPING STATION. BESIDES A POWER SUPPLY, CONTROL BOX AND A DISCHARGE HOSE
GALVANIC CORROSION PROTECTION (FOR SEA-WATER DUTY PUMPS ONLY) THE PARTS OF THE "MODY" SUBMERSIBLE PUMP THAT ARE IN CONTACT WITH SEA- W
6. THE SEAL CHAMBER CONTAINS APPROX. 5 LITERS OF OIL. THE LEVEL AND CONDITION OF THE OIL SHOULD BE CHECKED EVERY SIX MONTHS. UNSCREW THE OIL PLUGS
RE-ASSEMBLY OF THE PUMPSET. THE PUMP CAN BE RE-ASSEMBLED AS PER PROCEDURE GIVEN BELOW. PLEASE HOWEVER NOTE THE FOLLOWING: A) ALWAYS REPLACE NEW O